Home> Products > Multidrop Modems & Mux > TC2100
 
"Self-Healing Ring" Multi-drop Fiber Optic Modem
(Model TC2100)
Related Products:
TC2200, TC2400, TC2800, TC2900, TC3720

  • Async Data Rates to 38.4 Kbps
  • Single Ring or Self-Healing Ring
  • Sophisticated Tx/Rx Upstream, Downstream Fault Detection
  • Hardened Temperature (-40°C to 80°C) Optional, Exceeds NEMA & Caltrans Traffic Control Specs
  • Protocol Transparent: ModBus, DNP3, Telegyr, etc...
  • RS-232, RS-422 or RS-485
  • Local and Remote Loopback Tests
  • Test Signal Generator & Loop Monitor
  • Anti-Streaming (Anti-Jabber)
  • Local Dry Contact Alarm Relay
  • Multimode & Single Mode (850/1300/1550nm)
  • Extend Telephone Lines with TC1900 Phone to RS-232 or Fiber Extenders
Data Sheets: 4 pages (535 KB)



(Click on image to enlarge)

 

    "The TC2100s' Self-Healing function worked so well that several days went by before we realized that the fiber cable had been severed in one of the rings."
- Springfield Utility Board, OREGON

Download TC2100 SCADA application article 
4 pages (808 KB)


Applications

Renowned for its high reliability, the TC2100 Multi-Drop Modem is ideal for Ring or Self-Healing Ring communication links in SCADA, Traffic Control, Industrial Process Control and Security Networks.  It is frequently used to interconnect Remote Terminal Units (RTUs) or Programmable Logic Controllers (PLCs) in Utility substation SCADA Networks.

Top


Description                                        

The TC2100 Multi-Drop Fiber Optic Modem provides maximum reliability for linking monitoring devices (typically RTUs or PLCs) to a Host Controller or CPU.  It is available "substation hardened" and is transparent to data or communications protocols.

The TC2100 can be configured in Ring or Self-Healing Ring topologies.  The Self-Healing Ring scheme is sophisticated, i.e. it detects upstream and downstream failures on both Tx and Rx, and automatically re-routes any cable or equipment failure.  Multiple master units for maximum reliability are optional. It supports asynchronous data rates up to 38.4 Kbps.  Electrical interfaces are RS-232, RS-422 or RS-485.  The RS-485 electrical port can be multi-dropped.  A special version, Model TC2100X, is available for extreme temperature (-40°C to 80°C) applications.

Each TC2100 unit comes standard with two pairs of fiber interfaces and either 2-Channel RS-232 or 1-Channel RS-422/RS-485 interfaces.  The second channel on the RS-232 interface can be used for data, RTS/CTS handshaking signals or as a telephone extension with the Model TC1900 "Quick-Talk" Phone Extenders.

Local and remote Loopback is standard.  Sixteen diagnostic LEDs are provided.  Dry contact alarms can be connected to RTUs/PLCs to indicate specifically where a fault has occurred.  A test signal generator for verifying link integrity is provided to aid installation and troubleshooting.  "Anti-streaming" capability is standard.

The TC2100 is compatible with all popular types and sizes of fiber optic cable and is available multimode (850/1300nm) or single mode (1300/1550nm).  Fiber optic connectors are ST or FC.  Electrical connectors are DB25 female.  Power is 12VDC; optional 24VDC, -48VDC or 115/230VAC with an external power cube.

Note: Model TC2100 is the Master unit; TC2101 is the Slave unit.

Top


Technical Specifications    

Data Rates
Async RS-232, RS-422, RS-485 Up to 38.4 Kbps
Optical
Transmitter ELED
Receiver PIN Diode
Wavelength 1300nm Multimode
1300nm, 1550nm Single Mode
Fiber Optic Connectors ST or FC
Loss Budget*
(850nm, 1300nm, 1550nm)
Multimode (62.5/125µm): 15dB
Single Mode (9/125µm): 15dB
Electrical
Connector DB25 Female
Interface (DCE or DTE) RS-232, RS-422, or RS-485 (2 or 4 wire)
System
Bit Error Rate 1 in 10^9 or better
Diagnostic Functions
Local and Remote Loopback, Signal Generator, Disable Alarm, Loop Monitor

* Contact factory for higher requirements
Visual Indicators
System Status PWRA,  PWRB, Vcc, ALARM 
Optical Signal Status RxA, RxB, Sync-A, Sync-B
TC2100 (LPA, LPB, TXA, TXB) TC2101 (LPA, LPB, A2B, B2A)
Electrical Signal Status BRD-1, BRD-2, RSP-1,  RSP-2
Alarm 
Dry Contact Normal OPEN
Power
Standard 12VDC @ 500mA
Optional 24VDC, -48VDC, or 115/230VAC (with external power cube)
Temperature
Operating -10° to 50°C
High Temp (Optional) -20° to 70°C
Extreme Temp (Optional) -40° to 80°C
Storage -40° to 90°C
Humidity 95% non-condensing
Physical (Standalone/Wallmount Unit)  (Details)
Height (3.53 cm) 1.39"
Width (18.13 cm) 7.14"
Depth (16.59 cm) 6.53"
Weight (544 gm) 1.2 lbs

Top

 


Information Request Form                

Select the items that apply, and then let us know how to contact you.

Send product literature      Model:  
Have a salesperson contact me

      Name: 
     Title: 
   Company: 
   Address: 
    E-mail: 
     Phone: 
       FAX: 
  Comments: 
I Initially heard of TC Communications from:

  Google.com
  Yahoo.com
  MSN.com
  AOL.com
  Referral
  Magazine

  Other

                                 Top


© 2008, TC Communications, Inc.  All rights reserved.
17881Cartwright Road - Irvine, CA 92614
Tel:(949)852-1972, Sales:(800)569-4736 
Fax:(949)852-1948, sales@tccomm.com

Page Last Updated: 03/25/2008